Industrial Fiber Laser Cooling Solutions

Hanli Laser Chiller Water Chiller for Fiber Laser Systems

Industrial water-cooling solution for fiber laser cutting systems, designed to remove process heat and support stable operating temperatures for the laser source and associated cooling circuits.

Hanli laser chillers are industrial water-cooling units used with fiber laser equipment. The cooling system circulates temperature-controlled water to remove heat generated during laser operation and helps keep the laser system within its required operating temperature range. The supplied source identifies HanLi laser cutting chillers for 1064 nm fiber-laser applications and references configurations for laser systems from 1 kW to 20 kW. The exact chiller model must be selected according to laser power, required cooling capacity, electrical supply, flow, pressure and connection requirements. For correct selection, send SAKKARY MACHINERY the laser source brand and model, rated laser power, existing chiller model if replacing a unit, electrical supply and photos of the nameplates and water connections.

Hanli industrial water chiller for fiber laser cutting machine cooling system

What does a laser water chiller do?

A laser water chiller removes heat from the laser system through a controlled water-circulation circuit. Correct temperature control is an important part of maintaining stable laser operation and protecting temperature-sensitive components. The required configuration depends on the exact laser source and machine design.

Key functions

  •  Industrial water cooling for fiber laser equipment
  • Controlled circulation of cooling water
  •  Heat removal from laser-system cooling circuits
  • Support for stable operating temperature during production
  •  Configuration according to laser power and cooling demand
  • Replacement selection based on exact machine and chiller data

Typical applications

  •  Fiber laser cutting machines
  •  Industrial metal laser cutting systems
  •  Laser systems using compatible water-cooled fiber laser sources
  •  Replacement or service applications for compatible Hanli chiller installations

Selection criteria

  •  Laser source brand and exact model
  • Rated laser power (kW)
  • Required cooling capacity
  •  Chiller model and nameplate data
  •  Electrical voltage and frequency
  •  Required water flow and pressure
  •  Number and type of cooling circuits
  •  Inlet and outlet connection sizes
  •  Ambient operating conditions
  • Machine interface, alarm and control requirements
  •  Installation dimensions and available space

Technical information

The supplied product listing identifies the product as a HanLi laser cutting chiller for fiber-laser use and references 1064 nm applications and a 1 kW-20 kW laser-system range. These values describe the referenced listing and should not be applied to every Hanli model without verification.

Information required for quotation

  •  Laser machine brand and model
  •  Laser source brand, model and power
  •  Existing chiller brand/model, if applicable
  •  Clear photo of chiller nameplate
  •  Clear photo of laser-source nameplate
  • Electrical supply
  •  Photos of water inlet/outlet connections
  • Required quantity
  •  Any existing alarm or cooling problem

Important compatibility note

Do not select a laser chiller by laser power alone. Cooling capacity, flow, pressure, electrical supply, circuit configuration, communication/alarm interface and connection details must match the machine and laser source requirements.


Questions we are asked

What is a Hanli laser chiller used for?

It is used to circulate temperature-controlled cooling water in compatible industrial fiber-laser systems and remove heat generated during operation.

Can one chiller model be used with every fiber laser power?

No. The correct chiller depends on the laser source, rated power, required cooling capacity, flow, pressure, electrical supply and machine configuration.

What information is needed to select a replacement chiller?

Provide the laser source brand and model, laser power, existing chiller model and nameplate, electrical supply, connection photos and any alarm or failure information.

Is the 1 kW-20 kW range valid for every Hanli chiller?

No. The supplied source references Hanli chiller configurations for laser systems within this range. The exact supported power must be verified for the selected model.

Can SAKKARY MACHINERY help identify the correct chiller?

Send the machine and laser-source details, existing chiller information and nameplate photos so compatibility can be checked before quotation.

Tell us the tool or part you need

An engineer reads every request. Usually the same working day.

Request a price

Tell us what you needأخبرنا بما تحتاجه

  1. 01Needالاحتياج
  2. 02Categoryالقسم
  3. 03Detailsالتفاصيل
  4. 04Contactبيانات التواصل
What do you need?ما الذي تحتاجه؟
Need type